MECON - The right choice for flow and pressure test meters. We are a German certified manufacturer and provider of industrial test meters and level measurement instruments. As a relatively young company, we can boast an unusual wealth of experience as MECON was founded as the successor to the long-standing company TURBO WERK MESSTECHNIK, established in 1931. Since 1977 we produce VdS approved fire pump testmeters - now in the 3rd generation of the Turbo-Lux series. MECON is the unique manufacturer with the Turbo-Lux 3 fire pump testmeter who fulfils with one device the FM, LPCB and VdS approval. As a consistent further development of the stationary measuring systems, we are expanding our product range to include portable flow and pressure measuring instruments in the field of fire protection.

Products and services

Stationary Fire Pump Test Meters

Mechanical - Turbo-Lux 3 - FM, LPCB and VdS approved
• sizes from 2" / DN 50 to 12" / DN 300
• flow range: 20 to 10 000 USgpm (75 to 38 000 lpm)
• available ex stock

Electrical - Turbo-Lux 3 - digital
• be prepared for the future
• replace your mechanical indicator and be flexible with the digital version

Electrical - mag-flux T4 - VdS approved
• sizes from ½" / DN 15 to 12" / DN 300 (coupling / flange connection)
• sizes from G ½ to G 1 ½ (thread connection)
• short delivery times

Mobile / Portable Test Meters (Hydrant)

Electrical - mag-flux HTL - flow and pressure hydrant test meter
• sizes from Storz C (DN 40) to Storz 150 (DN 150)
• flow range: 0 to 3 361 USgpm (0 to 12 723 lpm)
• battery-operated up to 24 hours
• GPS receiver

Electrical - DLP - Data Logger Pressure - pressure & temperature measurement of water and gases
• pressure range: -14,5 to 435 psi (-1 to 30 bar) – optional more
• temperature range: 32° F to 392° F (0 °C to +200 °C)
• battery-operated up to 2 years
mag-flux HTL

Portable Hydrant Tester

• Nominal diameters from DN 40 (Storz C) from 0 ... 905 l /min. up to DN 150 (Storz 150) 0 ... 12,723 l /min.
• Rotatable and exchangeable Storz process connections
• Data memory for 2,000,000 measured values
• Data transmission via Bluetooth (in conjunction with LOG Control evaluation software)
• CE marking according to EMC Directive 2014/30/EU and RED Directive 2014/30/EU.

Further reading

Turbo-Lux 3 with FM, LPCB and VdS

Fire Pump Test Meter
• Sizes from 2" / DN 50 to 12" / DN 300
• flow range from 20 to 10 000 USgpm (75 to 38 000 lpm)
• large display in lpm, in % and USgpm
• always with accuracy certificate
• suitable for installation at any point
• insensitive to vibrations
• available ex stock

Further reading

mag-flux T4 with VdS approval

Electromagnetic Fire Pump Test Meter
• with VdS approval (compact and remote version)
• fully welded steel design for robust, error-free operation
• fast signal processing with 16-bit microcontroller
• permanently pre-configured measurement ranges
• sizes from ½" / DN 15 to 12" / DN 300 (coupling / flange connection)
• sizes from G ½ to G 1 ½ (thread connection)
• simple electrical connection thanks to M12 plug
• short in- and outlet sections
• 4 - 20 mA output
• short delivery times

Further reading

Address
MECON GmbH
Roentgenstr. 105
50169 Kerpen
Germany

Phone: +49 2237 600060
Internet: www.mecon.de
E-mail: Send message

Contact person

Michael Juech
Marketing & Sales Director
Phone: +49 172 4179600
E-mail: Send message

News & Innovations

Portable Data Logger Pressure (DLP)for measurement and recording of pressure, optional with temperature and pulse input, battery-powered
• Recording of pressure data for leak testing on gas and water pipes as well as geothermal probes
• Pressure recording in pipeline network (e.g. for a pipe network calculation)
• Pressure fluctuations in the network during water withdrawal (in conjunction with hydrant tester "mag-flux HTL")
• Pressure and temperature monitoring in gas pressure control stations
• Robust aluminium housing, anodized
• Memory for 2,000,000 measured values
• LC display, illuminated
• Manipulation-proof EEPROM
• Bluetooth Interface
• Operation via membrane keyboard or Software
• ATEX version (optional)
• Measuring accuracy: ±0.1 %
• Measuring ranges: -14,5 psi to 10,152 psi (-1/0 bar to 700 bar)
• Temperature range: +14 °F to +140 °F (-10 °C to +60 °C)
• Protection class: IP68
Portable Hydrant Tester (mag-flux HTL)for measuring flow and pressure (powered by rechargeable batteries, including data logger)
• Measuring range: 0 to - 3,361 USgpm (0 to 12.723 lpm)
• Connection: 2" Storz C rotatable to 6" Storz 150 rotatable
• Measuring accuracy: ±0,5 %
• Operating pressure Pe: max. 16 bar (232 psi)
• Media temperature: 34 to 104 °F (+1 to +40 °C)
• Protection class: IP54
• No moving parts
• Free flow (no additional pressure losses)
• Including pressure sensor
• Including data memory for 2,000,000 measured values
• Data transmission via Bluetooth TM 3.0 (can be used in conjunction with LOG Control software)
• 5 inch LCD display, backlit display (240 x 128 pixels)
• GPS module available
• System languages: English, French, German, Italian
• Great stability Made in Germany

Further reading

Click here if you notice an image that violates copyright or privacy rights.

Get in contact
OK

We use cookies and the web analysis tool Matomo in order to optimally design and continuously improve our website for you. By continuing to use our website, you agree to this. Further information and an objection possibility can be found here: Data protection